Pressure on 410a refrigerant - R-410A Environmental Classification HFC Molecular Weight 72.6 Boiling Point (1atm,°F) -61.0 Critical Pressure (psia) 691.8 Critical Temperature (°F) 158.3 Critical Density (lb./ft^ …

 
Most technicians in the HVAC field know the normal range of operation for the low-pressure side of an air conditioning system. This tends to be around 60 PSI to 85 PSI for R-22 and 105 PSI to 143 PSI for R-410A and is dependent upon operating conditions. On the high-pressure side of the system, there is a wide variation in …. Titan bow bg3

Freon ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically ...The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi.1 Mar 2022 ... If it is more than this, it is considered high. This will also depend on the weather and other conditions.Refrigerants - Pressure vs. Temperature Charts Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Refrigerants - Saturation Pressures vs. Temperatures Temperature and pressure diagram for constant boiling refrigerants - imperial and SI units. Triple Points SubstancesThe purpose of refrigerator coils is to dissipate heat, not suck up electricity—or cash—out of your wallet. But that's what happens if you don't clean off those bad boys once in a ...Freon ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically ...The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi.Whether you're looking for a commercial open-air refrigerator or an under-counter freezer, our list of the best commercial refrigerators certainly has something for you. * Required...High-Pressure Appliance (prior to March 12, 2004, referred to by the EPA as higher-pressure appliance) An appliance that uses a refrigerant with a liquid phase saturation pressure between 170 psia and 355 psia at 104°F. This definition includes but is not limited to appliances using R-410A, R-22, R-401B, R-402A/B, R-404A, R-Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000. That's correct! Refrigerant 410a, also known as R-410a, is a hydrofluorocarbon (HFC) refrigerant commonly used as a replacement for R-22 in residential and light commercial air conditioning and heat pump systems. It has become the leading choice for such systems due to its high cooling capacity and significantly higher pressure compared to R-22. The weight of an empty R-410A refrigerant cylinder can vary, but it is typically around 20 to 25 pounds (9 to 11.3 kilograms). What refrigerant is replacing R410A? Several low-GWP refrigerants, such as R-32, R-454B, and R-452B, are being considered as replacements for R-410A in various regions.Eco-Safe R-410A Refrigerant & MrCool. August 10, 2016. By MR COOL. Eco-safe R-410A refrigerant is the new standard for American air conditioners and heat pumps. As you might expect, it’s also the main refrigerant we use here at MrCool. The government, of course, required companies like us to adopt refrigerants like R-410A, but do you know why?Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157Price. Refrigerant R410A is used in new equipment designed to run at high pressures. Our R-410A refrigerants are 100% virgin factory sealed that meet or exceed the ARI-700 standards. Whether you're buying a full pallet or just one cylinder, you'll get the lowest wholesale prices and FREE continental US shipping when you order.R-410A _____ SDS: R-410A Page 3 of 8 Current Issue Date: January 04, 2021 UNUSUAL FIRE AND EXPLOSION HAZARDS: R-410A is not flammable at ambient temperatures and atmospheric pressure. However, this material will become combustible when mixed with air under pressure and exposed to strong ignition sources.HVAC or Central Air Coolant Recharge Cost. HVAC Freon recharge costs $100 to $320 for R410A refrigerant or $180 to $600 for R22 Freon. An HVAC system should never need more Freon unless the system has a leak or the recharge is part of a repair. Hire a licensed HVAC technician to locate and repair any leaks before refilling the …Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the...This system uses R-410A Refr igerant which operates at higher pressures than R-22. No other refrigerant may be used in this system. Gage sets, hoses, refrigerant containers and recovery systems must be designed to handle R-410A. If you are unsure, consult the equipment manufacturer. Refrigerants - Physical Properties. 1) Production of R11 or CFC-11 was halted by the clean air act on January 1, 1996. 2) Production of R12 or CFC-12 (Dichlorodifluoromethane) was halted by the clean air act on January 1, 1996. 3) R22 or HCFC-22 is a single component HCFC refrigerant with low ozone depletion potential. designed for higher pressures encountered with R-410A. Saturation Pressure (psig): R-22 vs. R-410A AC System Considerations Because of its enhanced properties, Freon™ 410A systems will operate differently than R-22 systems. Comparative refrigerant properties provided below are based on refrigeration capacity per pound of refrigerant. Refer to ...The R410a systems also use synthetic oil for lubrication instead of mineral oil as in R22 systems. The synthetic oil is more soluble and more effective for the whole system. Therefore, R410a performs better than R22 and has improved machine performance. R410a Vs. … R410A Refrigerant. R410A, often known as Puron, is an industry mainstay. But it’s been under scrutiny due to its high GWP. Overview and Use. R410A is a common refrigerant in residential and commercial AC units. Despite its environmental impact, it’s still a go-to for many HVAC systems due to its performance and non-flammability. Pros Recently a new refrigerant, R-410A, has been formu-lated and currently is being used in the HVAC/R industry. It was developed primarily because the pro-duction of R-22 is scheduled to stop soon. The phaseout schedule for R-22, as mandated by the Environmental Protection Agency (EPA), will be dis-cussed in more detail at the end of …Please note that in converting enthalpy and entropy from SI to I/P units, = 0 at –40°F for I/P units). In the conversion equation below, H (ref) and S (ref) are the saturated liquid enthalpy and entropy at –40°C. For Suva® 410A, H (ref) = … The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi. Jun 7, 2021 · r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. Tools for Measuring Refrigerant Pressure. There are two trusty sidekicks in the HVAC world: the manifold gauge set and the electronic refrigerant pressure sensors. Manifold Gauge Set. Good old manifold gauges. They’re as classic as a ’65 Mustang and just as reliable. To satisfy industry regulations, the HVAC industry is transitioning from Puron (R-410A) refrigerant to Puron Advance (R-454B) by the year 2023. We talk about the implications for homeowners. Unless you work in HVAC (Heating, Ventilation, and Air Conditioning), you probably won’t need to know what R-454B refrigerant is, or why it’s a big deal. A refrigerant is a chemical that makes things cold. This article discusses poisoning from sniffing or swallowing such chemicals. A refrigerant is a chemical that makes things cold....You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examplesof how you can use this chart: Example 1: What is the pressure of r410a at 72 degrees Fahrenheit? We can see that at … See morePressure Relief Valves Pressure relief valves are designed and engineered to provide high-volume discharge primarily for use on liquid receiver applications above the liquid refrigerant level. Models are available with multiple seat configurations, high pressure settings, and certified for use with R410a refrigerant.30 Oct 2019 ... This video will explain you about safety precautions to be taken while handling R-410a refrigerant, it alos explain about pressure testing, ...Dec 18, 2023 · R-410A refrigerant costs approximately $8 to $12 per pound or about $200 to $300 per 25-pound container. Starting in 2020, the EPA banned the import and purchase of R-22 Freon. If you have an older unit that takes R-22 refrigerant, you can’t simply add R-410A because of the pressure differences between the two products. High-Pressure Appliance (prior to March 12, 2004, referred to by the EPA as higher-pressure appliance) An appliance that uses a refrigerant with a liquid phase saturation pressure between 170 psia and 355 psia at 104°F. This definition includes but is not limited to appliances using R-410A, R-22, R-401B, R-402A/B, R-404A, R-The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.Pressured speech is a compulsive urge to talk in a rapid, urgent way. This is a common symptom of bipolar disorder manic episodes. Pressured speech is when you talk in a fast, fran...Jan 16, 2023 · The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below. r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3In the example of an R-410A packaged unit with a surrounding air temperature of 70°F, the pressure on both the high and …Freon ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically ...Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22. Although R410A is a zeotropic refrigerant, the whole refrigerant behaves almost as if it was an azeotrope. This is because there are only two refrigerants in the mixture and these two refrigerants ...Some example high pressure refrigerants are as follows: R-12, R-22, R-114, R-500, and R-502. Also note that this type 2 certification will allow you to legally purchase and handle R-410A refrigerant. Type 3 608 Certification This covers low pressure appliances with some example refrigerants being R-11, R-113, and R-123. …Both the R454B and R410A are safe to use. They are both non-toxic and stable inside any refrigeration system. Also, when handled by an expert, you can expect both to be safe to use. However, R454B seems to be mildly flammable if exposed to atmospheric pressure. It has a A2L ASHRAE classification.Feb 26, 2024 · R-32 Refrigerant. R-410A is a perfectly good refrigerant, but there’s a new product on the market: R-32 coolant. R-32 has only one-third of the GWP than R-410A, uses 20% less refrigerant, is easier to recycle, and is more efficient. These qualities make it an even more environmentally-friendly alternative for keeping your home comfortably cool. 1000 600 400 200 Enthalpy (BTU/lb) 140 410A Refrigerant (R-410A) P-H Diagram (ENG Units) Enthalpy (BTU/lb)The R410a systems also use synthetic oil for lubrication instead of mineral oil as in R22 systems. The synthetic oil is more soluble and more effective for the whole system. Therefore, R410a performs better than R22 and …Mar 16, 2024 · The purpose of the 410A PT Calculator is to accurately determine the pressure of R-410A refrigerant at various temperatures. Given the non-linear relationship between temperature and pressure for R-410A, the calculator provides a quick and accurate way to perform these calculations, essential for efficient HVAC system design, troubleshooting ... R410A PRESSURE-TEMPERATURE CHART. Saturation Pressure-Temperature Data for R410A (psig)*. ECLPC-1 Rev 1 – 02/22. Created Date. 2/25/2022 1:24:53 PM.The purpose of refrigerator coils is to dissipate heat, not suck up electricity—or cash—out of your wallet. But that's what happens if you don't clean off those bad boys once in a ...What is an R410A PT Chart? An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems.LOW HIGH Need service, possible blockage of the e HIGH LOW Needs service, possibly faulty compresso. What is the standing and discharge pressure of a refrigerant? Refrigerant pressure readings R-22, R-410A, R-290, R-417A 1 Standing pressure – 150 PSI 2 Saction pressure – 60 TO 70 PSI 3 Discharge pressure – 250 …National Refrigerants, Inc. Product Data Summary and Thermodynamic Tables 48 Refrigerant Reference Guide 7th Edition 2020 R-410A! AVAILABLE IN SIZES "REFRIGERANT Type Size R-410A Cylinder 25 lb. 100 lb. 850 lb. 1,450 lb. R-410A Composition: (R-32 / 125) • (50 / 50 wt%) Application: Air conditioning equipment and heat pumps. Only for newly Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37-36 ... Jul 5, 2019 · Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:... system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3. Pressured speech is a compulsive urge to talk in a rapid, urgent way. This is a common symptom of bipolar disorder manic episodes. Pressured speech is when you talk in a fast, fran... Saturation Pressure-Temperature Data for R410A (psig)*. ECLPC-1 Rev 1 – 02/22. This article refers to troubleshooting refrigerant charge on 410a and R22 residential air conditioning systems. Although many of the principles will carry over to other types of refrigerants and drop-ins. ... R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply ...410A operates at a much higher pressure than R-22, between fifty to sixty percent higher. To accommodate this increased pressure the compressors and other components are built to withstand …R-22 is a low-pressure refrigerant while R-410A operates at higher pressures. When you combine these two different systems, you can very easily cause damage to your equipment, or worse, harm yourself. If you put R-410A into an R-22 system, the compressor will not be able to handle the higher pressure and will blow the seals off of the compressor.Experiments are carried out here to measure the evaporation heat transfer coefficient hr and associated frictional pressure drop ΔPf in a vertical plate heat exchanger for refrigerant R-410A. The heat exchanger consists of two vertical counterflow channels which are formed by three plates whose surface corrugations have a sine shape and a …™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems Technical Information Freon™ 410A provides comparable performance to R-13B1 in most very low temperature, (VLT) applications. R-13B1 is an ozone-depleting refrigerant, and production has ... Saturation Pressure-Temperature Data for R410A (psig)*. ECLPC-1 Rev 1 – 02/22. After assembly, the unit is pressurized with a combination of The 7.5 thru 20 Ton blower module includes the blower Refrigerant R-410A and nitrogen for pressure testing and wheels along with factory-mounted motor and drive. The 25 additional leak testing. During this pressure test, the Ton blower module includes the blower wheels with field ...The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below.High pressure refrigerants, like R-410A, work under greater pressure levels than their counterparts. But aren’t all pressurized systems a bit intimidating? You’d think so, but their high efficiency might change your mind. ... Low pressure refrigerants, such as R-123, R-11, and R-113, operate at pressures that are actually lower than the ...Whether you're looking for a commercial open-air refrigerator or an under-counter freezer, our list of the best commercial refrigerators certainly has something for you. * Required...Because R-410A differs from R-22 in several respects, including operating pressure, some trade schools offered classes and certifications for R-410A specifically. These are not equivalent to a section 608 certification.designed for higher pressures encountered with R-410A. Saturation Pressure (psig): R-22 vs. R-410A AC System Considerations Because of its enhanced properties, Freon™ 410A systems will operate differently than R-22 systems. Comparative refrigerant properties provided below are based on refrigeration capacity per pound of refrigerant. Refer to ...Freon™ 407C and 410A Refrigerants 10 Thermal Decomposition Like HCFC-22, Freon™ 407C and Freon™ 410A refrigerants will decompose when exposed to high temperatures or flame sources. Decomposition may produce toxic and irritating compounds, such as hydrogen fluoride. The decomposition products released will irritate the nose and throat.3 Aug 2020 ... Question: An air conditioner with refrigerant R-410a has a high-side pressure of 340 psig and a temperature of 95°F. According to the ...Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information.Freon™ Pressure/Temperature Chart App. The P/T Calculator provides technicians with refrigerant data on the go. Learn More. Sales & Support. Where to Buy; ... Freon™ 410A (R-410A) Refrigerant; Freon™ MO29 (R-422D) Refrigerant; Freon™ MO59 (R-417A) Refrigerant; Freon™ 123 (R-123) Refrigerant;Understanding R410A Refrigerant. R410A refrigerant, also known as Puron, Forane 410A, Genetron R410A, EcoFluor R410, and Suva 410A, is a popular choice for air conditioning applications. It has a higher cooling capacity and is more energy-efficient than older refrigerants like R-22.FreonTM 410A has higher operating pressures compared to R-22. FreonTM 410A is for new equipment that is specifically designed for R-410A. FreonTM 410A will require use …Freon ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically ...Price. Refrigerant R410A is used in new equipment designed to run at high pressures. Our R-410A refrigerants are 100% virgin factory sealed that meet or exceed the ARI-700 standards. Whether you're buying a full pallet or just one cylinder, you'll get the lowest wholesale prices and FREE continental US shipping when you order.Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157To satisfy industry regulations, the HVAC industry is transitioning from Puron (R-410A) refrigerant to Puron Advance (R-454B) by the year 2023. We talk about the implications for homeowners. Unless you work in HVAC (Heating, Ventilation, and Air Conditioning), you probably won’t need to know what R-454B refrigerant is, or why it’s a big deal.

A refrigerant is a chemical that makes things cold. This article discusses poisoning from sniffing or swallowing such chemicals. A refrigerant is a chemical that makes things cold..... Truist short pump

pressure on 410a refrigerant

Nov 15, 2023 · 1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2. On to what’s changed. Ok, so obviously the refrigerant has changed but the big and noticeable difference here is the pressure change. 410A is anywhere from fifty to sixty percent higher pressure than R-22. So, while the basic design and operating procedures of 410A remain the same as R-22 extra caution should be paid to the pressure of 410A.A refrigerant is a chemical that makes things cold. This article discusses poisoning from sniffing or swallowing such chemicals. A refrigerant is a chemical that makes things cold....Refrigerants - Pressure vs. Temperature Charts Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Refrigerants - Saturation Pressures vs. Temperatures Temperature and pressure diagram for constant boiling refrigerants - imperial and SI units. Triple Points SubstancesThat's correct! Refrigerant 410a, also known as R-410a, is a hydrofluorocarbon (HFC) refrigerant commonly used as a replacement for R-22 in residential and light commercial air conditioning and heat pump systems. It has become the leading choice for such systems due to its high cooling capacity and significantly higher pressure compared to R-22.Are refrigerants available for home air conditioners that do not harm the ozone layer? Yes, a number of ozone-friendly refrigerants are available and widely used today. The most common alternative in new AC systems is R-410A, which is known by trade names such as GENETRON AZ-20 ®, SUVA 410A ®, Forane ® 410A, and Puron … Saturation Pressure-Temperature Data for R410A (psig)*. ECLPC-1 Rev 1 – 02/22. Suvaâ 407C and Suvaâ 410A Refrigerant Descriptions. Suva® 407C is a non-ozone-depleting blend of three hydrofluorocarbon (HFC) refrigerants. It exhibits performance characteristics similar to R-22. Suva® 410A is a non-ozone-depleting blend of two HFC refrigerants. It exhibits higher pressures and refrigera-tion capacity than R-22.R410A refrigerant cannot be reclaimed like R32, as the former is a blend. R410A operates at high pressures, which poses safety hazards. Because of these pressures, R410A requires thicker compressors and pipes to withstand the pressure, which may affect the design of your house.The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi.Although the market prices change constantly, you can expect to pay $4-$6 dollars per pound for R410A. R22 can cost up to $35 per pound, though about $20 per pound, as this shot shows. Note the number of pounds and the cost. 5lbs of R22 is $169 or about $34 per pound. 10lbs of R22 is $219, or almost $22 per pound.Recently a new refrigerant, R-410A, has been formu-lated and currently is being used in the HVAC/R industry. It was developed primarily because the pro-duction of R-22 is scheduled to stop soon. The phaseout schedule for R-22, as mandated by the Environmental Protection Agency (EPA), will be dis-cussed in more detail at the end of …Composition of refrigerant r410a. Refrigerant R410-a is a two-component substance. The composition of the r410a refrigerant includes: Refrigerant r32, difluoromethane (50%); Refrigerant r125, pentafluoroethane (50%). The components that make up 410 refrigerant gas have similar characteristics and the dependence of boiling …Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157 All welded OEM pressure transmitter for use on refrigeration application with R22 and R410A refrigerant up to 400 psig. 17.609G Pressure Transmitter. 17-609G data sheet; Pressure Range: 0 – 400 psi g; Output: 4 – 20mA / 2 wire; Supply Voltage: 8 – 32V dc; Electrical Connection: Male & female plug ISO 4400 Composition of refrigerant r410a. Refrigerant R410-a is a two-component substance. The composition of the r410a refrigerant includes: Refrigerant r32, difluoromethane (50%); Refrigerant r125, pentafluoroethane (50%). The components that make up 410 refrigerant gas have similar characteristics and the dependence of boiling point and pressure.Brand: Weitron. Refrigerant: R-410A. Dimension: 10"W x 17"H. Weight: Net 25 lb. Valve fitting: 1/4-inch RH thread. Additional freight charges will apply for shipments outside our local delivery areas. R410a-25. View the R-410A Refrigerant and more. With HVAC R-410A refrigerant tanks fully stocked - we have what you need, when you need it.Properties of R410A Refrigerant. The R410A is a type of hydrofluorocarbon (HFC) refrigerant commonly used in AC systems, heat pumps, and commercial HVAC equipment. It was developed as an environmentally friendly alternative to older freon refrigerants like R-22. It has several benefits over traditional freon refrigerants, including a lower risk ... Forane 410A Pressure Temperature Chart Forane 410A, R-410A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 ….