Limit circuit fault furnace - Beginning January 1, 1992, all furnaces were manufactured with an integrated furnace control board, often referred to as FCB (Furnace Control Board). The FCB manages all operation requirements of the furnace. Fault and Information codes are displayed by one or more LEDs on the board. The FCBs used by York/JCI have the ability to store Read More...

 
A properly chosen panel would not allow high fire if only one zone were calling. And a good panel would have a thermistor in the supply that shut off the furnace before the furnace's limit did. You let the furnace's limit open a few times and it will like to stick open leaving you cold. Reply. 10-23-2010, 12:22 PM #5.. Early times auction house

Page 19: Status Code 4 - Limit Circuit Fault Status Code 4 LIMIT CIRCUIT FAULT - This status code indicates the limit, flame rollout switch is open, or the furnace is operating in maximum-heat only mode due to 2 successive limit trips while operating at any rate < 71% of maximum rate.Circuit Breaker/Fuse: Most likely, either the electrical system providing your furnace's power has shorted or the power switch has blown. Try resetting your furnace's circuit breaker. If it has blown, you will need to replace it. Igniter: The furnace's igniter might either be cracked or faulty.22 Aug 2018 ... Gas furnace not igniting - Goodman furnace wont ignite - DIY Gas furnace repair ... Furnace is in lockout mode! MR HVAC101•10K views · 6:03 · Go ...location on the burner, furnace or wall. The location must not exceed the ambient temperature limit, 140°F. ... Call for heat Set thermostat (or limit) to call for heat. Thermostat circuit must be closed and power coming to black wire from limit circuit. Self-test 2 The amber LED turns on. For the first 3 to 4 seconds, the control per- ...Advertisement Oil-fired burners are used in many parts of the country as the basic heat source for warm air and hot water heating systems. Most of the home oil systems in use today...I believe Code 13 is the Limit circuit lockout and Code 33 is the Limit circuit fault. These codes can show with a blocked vent, dirty filter. If the vent is blocked, the draft safeguard switch will shut off the furnace and will automatically reset after the furnace cools off.Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, …4 posts · Joined 2012. #1 · Nov 23, 2012. My American Standard Freedom 90 Furnace only ignites about 50% of the time. It appears that the ignitor turns off a split second before the gas valve is opened. I replaced the ignitor hoping that a new one would get hotter and stay hotter for a split second longer, but it still only works about 50% of ...Steps to Safely Reset Your Concord Furnace. Power Off: Begin by switching off the furnace. You can do this by turning off the switch located on or near the furnace or by flipping the appropriate circuit breaker in your home’s electrical panel. Wait: Allow the furnace to sit without power for a few minutes.For more technical tips, visit edgetekhvac.comThese technical tips are for licensed HVAC contractors only.A carrier furnace code 13 indicates that the limit switch is open. If the limit switch opens 5 times for at least 3 minutes each time during 1 thermostat cycle this will trigger the status code 13. This status code is associated with overheating within the furnace causing the limit switch to open. With that said, there are a few things that can ...Want to learn how to reset a circuit breaker? It's easy to get your devices back up and running after a circuit breaker trips. Advertisement Most homes use circuit breakers that tu...Teahouse accommodation is available along the whole route, and with a compulsory guide, anybody with the correct permits can complete the circuit. STRADDLED BETWEEN THE ANNAPURNA M...Follow the red to the roll out switch (s). The red wire just makes a loop starting at the board and ending at the board. on the rollout switch, there should be a small button between the wires. It may be red or black. Press that and see if you feel it click. Then retry the furnace.24-vac terminal block on the furnace control (See Appendix A). This furnace can be installed with either a single-stage heat/cool or a two-stage heat/cool thermostat. This furnace is equipped with a manual reset limit switch in the gas control area. The switch will open and shut off power to the gas valve, if a flame rollout or overheating ...Nov 29, 2023 · Meaning: Indicates a limit circuit fault, such as a flame rollout or an open limit, which are serious safety concerns. Action: Check for a loose blower wheel, blocked vent, correct vent sizing, dirty filter, or a defective blower motor. Ensure that all connections and switches are functioning properly. Furnace bryant trane troubleshooting device condensing faultLimit circuit fault but house keeps warm Single stage furnace limit circuitDucane furnace model image0 hvac. Check Details. My furnace was attempting to cycle and i read to clean the flame sensor. I've got a open limit switch fault indicator light on my furnaceLimit circuit furnace ...33 - Limit fault. Contractor's Assistant: Have you tried resetting the control system to see if that resolves the issue? 33- Linit Fault 59 Events Active. Contractor's Assistant: Is there anything else the HVAC Tech should know before I connect you? Rest assured that they'll be able to help you. Fan is on; Furnace is offRemove the cover (if one is present) to reveal the body of the switch. Set the fan limits: You'll see a temperature setting if you check between the two arms. This value controls the furnace's fan. It's the temperature at which the fan switch comes ON when the furnace is running. Set it to 105°F-115°F.Furnace Generated Fault Codes. When it comes to the furnace component of a Carrier Infinity system, fault codes can help identify and address problems promptly. These fault codes serve as valuable indicators of issues such as blower motor faults, limit circuit lockouts, or ignition lockouts. By familiarizing themselves with these codes, users ...This month's topic is Ignition Failure Faults and Troubleshooting Tips. Ignition Failure Fault Codes: 7 Red Flashes - Flame could not be sensed after 5 tries for ignition. 8 Red Flashes - Flame has been sensed, then lost 5 times during a call for heat. Rapid Amber Flash - Flame Sense Current is low.Auto reset after three hours. Check for improper or misaligned limit and/or limit shield, improper high or low heat gas input adjustment, and stuck high heat solenoid in the gas valve. CODE: 14. Problem: Ignition lockout. Solution: Control will auto-reset after three hours. Refer to #34 for further troubleshooting. CODE: 21.Step 1—Self-Test Mode The control center goes through a brief self test whenever 115-v or 24-v power is interrupted. The self test takes approximately 2 secI have a limit circuit fault code 33 - Answered by a verified HVAC Technician. ... my programmable carrier thermostat screen goes blank when the furnace trips off from the hi limit switch. the light comes on when i reset the limit switch .The code is 33 all the time when it happens, ...No heat. Nordyne G7 fault, Open limit switch Fault. 1. When unit is off, both red/green leds lit (normal), 2. once thermostat temp is raised, fan starts, aux fan on exhaust starts, Green LED flashes, … read morecode 13: limit circuit lockout code 33: limit circuit fault ... The most common cause of a limit trip is airflow thru the furnace. A dirty filter, clogged A/C coil ...LIMIT CIRCUIT FAULT: Indicates a limit or flame rollout is open. 5: FLAME SENSED WITH GAS VALVE OFF: Inducer will continue to run until fault condition is cleared. 6: IGNITION PROVING FAULT: Failure to sense flame. 4 consecutive faults will cause a 6 + 1. 7: LIMIT CIRCUIT LOCKOUT: Limit circuit open for more than 3 minutes. Auto-Reset after 3 ...No heat. Nordyne G7 fault, Open limit switch Fault. 1. When unit is off, both red/green leds lit (normal), 2. once thermostat temp is raised, fan starts, aux fan on exhaust starts, Green LED flashes, … read moreWhat is the furnace error code limit switch open diagnostic code or whatever it is called?It depends on the furnace brand. Four flashes on a York furnace may...Feb 14, 2018 · Learn how to troubleshoot an open limit fault on a furnace. These tips are for licensed HVAC technicians only. For more tips visit edgetekhvac.com My Carrier furnace is blinking code 13: limit circuit lockout. If I unplug the furnace and plug back in with the thermostat set in the off position, I get a continuous red light, which the code reads Control has 24VAC Power. When I turn on heat, the heat blowers run, and then the fan comes on. When this happens the Code switches to 33.Buying a mobile home can be a great investment for some. The option of designing your own living space, having it built and shipped to you is a big attraction. It can also be more ...The furnace will start up in either intermediate-, or maximum-heat. The furnace will transition and operate at minimum-heat or the calculated modulating rate after starting and operating for 45 seconds at intermediate-heat. The furnace control CPU defaults to minimum-heat on the first thermostat cycle and calculates the modulating rate33 LIMIT CIRCUIT FAULT – Indicates the limit, or flame rollout is open or the furnace is operating in high-heat only mode due to 2 successive low heat limit trips. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. Page 9: Start HereI show up and find many instances of 33- Limit Fault, and 42- Inducer Motor Fault. ... Code 33 is a limit circuit fault. ... I had a similar fault code 33 on the very same furnace with 80K and what fixed the problem was checking the manifold pressure of both low and high fire as the original installers never bothered to do so .Customer liked to ...Limit circuit fault: either a limit or flame rollout is open: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower: Five LED flashes: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized: Check for a leaky gas valve or a gas valve that is stuck open ...Three or Four Blinks. Three LED blinks with a two-second pause indicates the limit switch is closed. A limit switch is a safety feature directly wired into the furnace; it stops a furnace from overheating if air isn't properly flowing through the heat exchanger. If the switch is closed, debris might be clogging the filter or the blower fan housing.Learn how to troubleshoot an open limit fault on a furnace. These tips are for licensed HVAC technicians only. For more tips visit edgetekhvac.comNordyne furnace #fg6ra072c-012a limit circuit open. ... He has helped you determine that the high limit switch is at fault. This shouldn't be left jumped out or an unsafe condition could result. He had you do it to test it. Do you have access to an electrical meter?protection against short circuit or overload conditions. Anti-Short Cycle Protection - 4 minute anti-short cycle protection for the compressor. Random Start - 5 to 80 second random start upon power up. Fault Retry - in the fault condition, the control will stage off the outputs and then "try again" to satisfy the thermostat Y input call.OVERFIRE - ensure furnace is not overtemperature (temp rise is above stated range). Check gas valve, proper orifice size, gas pressure, etc. Is Limit circuit open or opening and closing? Note: IFC Status LED should be blinking a Fault Code. Is the IFC sensing a good flame: NOTE: Flame sense light should be steady-on when burners are lit. The furnace will start up in either intermediate-, or maximum-heat. The furnace will transition and operate at minimum-heat or the calculated modulating rate after starting and operating for 45 seconds at intermediate-heat. The furnace control CPU defaults to minimum-heat on the first thermostat cycle and calculates the modulating rate Typically, tripping is because of one of three reasons: an inefficient furnace filter, faulty wiring or installation, or not enough airflow coming into the furnace. Here's what causes the furnace high limit switch to keep tripping: 1. Short cycling. The high-limit switch is designed to shut down the furnace if it senses something has gone ...Upvote. Gas and Oil Home Heating Furnaces - Carrier Infinity limit switch fault #33 - I have a carrier 58mvc that I'm getting a code 33. The FRS isn't tripping but the LS is, I have a humidifier application on it and with the humidifier cover and screen removed along with the air filter door removed the LS is still tripping.By interpreting these Trane furnace codes, users can swiftly identify specific needs, such as adjusting airflow or checking combustion, and address concerns to maintain optimal function. One amber flash: Call for cooling. Two amber flashes: Call for heat. Three amber flashes: Temperature fulfilled, burner ending cycle.Dec 2, 2010 · It seems to function fine in all modes HP high/low and furnace low. only problem seems to be a high furnace heat call and then only after 15-30 min of operation. Reply Page 1 of 2 1 2 Last Furnace bryant lockout failed bl payne indicates blower owerI've got a open limit switch fault indicator light on my furnace Carrier comfort 92 furnace 33 limit circuit fault to 13 limit circuitMy furnace is not coming on. the power is working, and the led status. Check Details Limit circuit fault, need second advice (carrier 58mvb)Jan 22, 2024 · Frequency: Check and replace your furnace filters every 1-3 months, depending on usage and the type of filter. Benefits: Clean filters improve air quality and furnace efficiency while reducing strain on the system. Annual Professional Inspections. Scheduling: A certified HVAC technician inspects your furnace annually, ideally before the heating ... Bryant furnace: limit circuit lockout bryant furnaceHave a carrier 48gs-030060301 package, the fault code is 1 flash=fan on Power line carrier channel (plcc) and application of transmission lineCarrier infinity thermal lockout.Step 1—Self-Test Mode The control center goes through a brief self test whenever 115-v or 24-v power is interrupted. The self test takes approximately 2 secThe furnace is operating in high heat. If you are a lucky owner of a two-stage furnace, then you should know that your unit has two heat settings - low-heat and high-heat. The majority of the time, the furnace will be operating in low-heat mode, but when it becomes very cold outside, the unit can switch to the high-heat setting. The code thrown was limit circuit lockout. When the technician was here he asked a lot about if all my registers were open which was an easy yes and diagnosed that if my furnace has been tripping a lot I should get the switch replaced. He set my furnace to only use first stage heat and left getting me that part ordered. Feb 21, 2016 · Fixing my carrier comfort 92 high efficiency furnace after it threw the #13 and #33 limit circuit error code. Full write-up at http://chris-eigenheer.blogspo... Also, what exactly is a limit circuit fault? [4] LIMIT CIRCUIT FAILURE – Indicates whether the furnace’s limit, a flame rollout switch, or high-heat only mode is being used due to two successive low-heat limit trips. The blower will run for about 4 minutes. or until open switch remakes are completed, whichever is longer.Carrier furnace code 13 is a limit circuit lockout error, which means that the furnace has tripped its limit switch and will not reset until it has cooled down. This can be caused by a variety of issues, such as a clogged air filter, a blocked vent or flue, or a malfunctioning blower motor.Furnace Generated Fault Codes. When it comes to the furnace component of a Carrier Infinity system, fault codes can help identify and address problems promptly. These fault codes serve as valuable indicators of issues such as blower motor faults, limit circuit lockouts, or ignition lockouts. By familiarizing themselves with these codes, users ...ISSUE: Limit circuit fault. ... ISSUE: Limit circuit lockout. ... FIX: Correct line voltage polarity, could also have burnt wiring harness inside the furnace, burnt a spot on the circuit board. Best to have a licensed technician look this over. CODE: Status codes 1 + 2. ...Status codes 4 + 2. Inducer motor fault. Proper vent sizing; restricted vent; failed inducer motor; improper motor wiring; a blockage in the tubing to the pressure switch assembly. Status codes 4 + 3. The low or medium pressure switch is open while the medium or high-pressure switch is closed.Satisfied Customers: 26,621. Experience: Endorsed for unlimited heating, cooling, oil burners, boilers, refrigeration, hydronics. Verified. BillyHvac and 87 other HVAC Specialists are ready to help you. Ask your own question now. Share this conversation. My heater keeps flashing an open limit switch code. The.If your furnace is malfunctioning, the problem could very well be a faulty limit switch, but since it's a safety device, it may be operating normally, and the culprit could be something else. Testing a limit switch is a DIY task that requires only a screwdriver and a multimeter, and if the switch is faulty, it's easy to replace. Video of the Day.When the draft inducer is working as it should, the pressure switch then completely closes the circuit (turns on). Issues. When there is an issue with the draft inducer motor, the pressure switch will then open or turn off. The furnace then shuts down to prevent ignition since there could be a buildup of those dangerous gases.Ducane gas furnace three flashes code signals that rollout, aux limit switch are open or the fire pressure is low. Code-4 flashes. Ducane furnace 4 LED blinking lights to inform that the high limit switch is open. Code- 5 Flashes. It's not used. Code- 6 Flashes. The six flashes code informs that the pressure switch cycle is in a lockout. Code ...Limit circuit fault: either a limit or flame rollout is open: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower: Five LED flashes: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized: Check for a leaky gas valve or a gas valve that is stuck open ...If the air inside your furnace gets too hot, the limit switch trips to prevent overheating. If the furnace high limit switch trips due to overheating, there is likely an airflow issue that is preventing proper air movement through the system. Check your air filter, and replace it if dirty. A dirty filter is the most common cause of airflow issues.Tempstar Furnace Age, Manuals, Parts Lists, Wiring Diagrams PDF Downloads & Contact Info. Also Heil, ICP, International Comfort Products & Carrier gas furnaces. ... Limit circuit fault: Check for dirty air filter. Check for loose switch connections. ... Limit circuit lockout: Auto reset after 3 hours. See code 4. 8 flashes: Gas heat lockout ...According to the sticker inside my furnace access door a code 33 means a limit circuit fault caused by: Dirty and/or clogged air filter. No--I replaced my air filter on less than 3 weeks ago. Air filter is a larger Aprilaire filter and not the common 1" thick fiberglass strand type filter. Blocked vents or air returns.To all technicians receiving a 33-Limit Fault Code. I has a major issue with a 59MN7 Modulating Furnace. These numbers were the result of running the system on High-Fire for 5 minutes. Excess Air%=40% - Carrier will tell you 40% Excess Air on a 59MN7 is not low and is in fact a great Excess Air Percentage. *Within 5min of run time the 33-Limit ...GMC vehicles are produced by General Motors. GMC specializes in sport utility vehicles, trucks and vans. If your GMC vehicle sets off a fault code, also known as a check-engine cod...Locate the furnace's circuit breaker in the electrical panel and check if it's tripped. If it has, reset it. Also, ensure that the furnace's power switch, often located near the unit, is in the "on" position. ... Fault with the limit switch. 34: Ignition proving fault has occurred. 41: Blower speed is outside the valid range. 42:Turn power off, disconnect wires one limit at a time and check resistance across each. should be at or near zero ohms if closed. Likely this furnace has one main limit, as well as rollout switches near the burners. The rollouts are manual reset, there's a button - if one is tripped, reset once, if it trips again do not reset again and call a ...the 33 is a limit, a limit would typically be any switch that break the 24volt circuit for the heat, could be the little discs the red wires attach to, by the inducer motor, the roll out switches, but if you can get the furnace to come back on without depressing any switches, it's probably the high limit, which means the unit if overheating.33 LIMIT CIRCUIT FAULT – Indicates the limit, or flame rollout is open or the furnace is operating in high-heat only mode due to 2 successive low heat limit trips. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. Page 9: Start HereMy Carrier Furnace is continuously blowing and the heat doesn't work. The code was first, Limit Circuit Fault, tnen after changing the filter, it went to Limit Circuit Lockout -- and it is still blowing cold air. (Yikes!! It got down to 10 degrees outside)Always install a furnace to operate within the furnace's intended temperature-rise range with a duct system which has external static pressure within the allowable range, as specified on the furnace rating plate and OPERATIONAL CHECKS section of these instructions. When a furnace is installed so that supply ducts carryI had a Carrier Heating/AC unit installed during the summer of 2004. The first winter the system would not come on or when it did only heat with very low or no fan speed. It displayed a Code 13 Limit Circuit Lockout which also refers to Code 33 Limit Circuit Fault. The HVAC technician could find nothing wrong and said the items listed under Codes 13 and 33 were not the problem.Auto reset after three hours. Check for improper or misaligned limit and/or limit shield, improper high or low heat gas input adjustment, and stuck high heat solenoid in the gas valve. CODE: 14. Problem: Ignition lockout. Solution: Control will auto-reset after three hours. Refer to #34 for further troubleshooting. CODE: 21.Here are a few possible causes of tripped flame rollout switch: 1. Clogged exhaust vent. A clogged exhaust vent will restrict airflow through your heat exchanger. If airflow is restricted through the heat exchanger, then flame rollout can occur. Be sure to check your exhaust vent for any possible obstructions.Carrier model 58sta070-12...flashing code 33,(limit circuit fault),,,,furnace ignites,blower barely turns for - Answered by a verified Home Improvement Expert. We use cookies to give you the best possible experience on our website.Troubleshoot the fault code as necessary. If wet on floor or in the furnace: Check the condensate drain and “P” trap. If blocked, remove the blockage. If the fan does not start running: Check the fuses or circuit breakers for the furnace and heat pump. Reset tripped breaker and/or replace blown fuses.Always install a furnace to operate within the furnace's intended temperature-rise range with a duct system which has external static pressure within the allowable range, as specified on the furnace rating plate and OPERATIONAL CHECKS section of these instructions. When a furnace is installed so that supply ducts carry

Learn how to troubleshoot an open limit fault on a furnace. These tips are for licensed HVAC technicians only. For more tips visit edgetekhvac.com. Kobalt battery flashing green

limit circuit fault furnace

Given below are the 3 steps needed to reset your Lennox furnace -. Switch off the electrical supply to your Lennox furnace which is present in an electric panel. This will eradicate the risk of any electrical devastations. Turn off the circuit breaker switch tagged "Furnace" or "Heating System". Look at the control panel on your ...protection against short circuit or overload conditions. Anti-Short Cycle Protection - 4 minute anti-short cycle protection for the compressor. Random Start - 5 to 80 second random start upon power up. Fault Retry - in the fault condition, the control will stage off the outputs and then "try again" to satisfy the thermostat Y input call.CODE: Four LED flashes PROBLEM: Limit circuit fault: either a limit or flame rollout is open FIX: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower CODE: Five LED flashes PROBLEM: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized FIX: Check for a ...Troubleshooting the Open Limit Fault - YouTube. Nortek Global HVAC. 15.1K subscribers. Subscribed. 57. 15K views 6 years ago. Learn how to troubleshoot an open limit fault on a …One way you can fix code 13 on your furnace is by checking for continuity in the high limit switch. However, for safety purposes, you should only do so after the furnace has cooled down. If you notice that the high switch limit is still open, then you have a faulty switch. Fix the switch or get a new one for effective use.If the air inside your furnace gets too hot, the limit switch trips to prevent overheating. If the furnace high limit switch trips due to overheating, there is likely an airflow issue that is preventing proper air movement through the system. Check your air filter, and replace it if dirty. A dirty filter is the most common cause of airflow issues.Bryant furnace code 33 (3 short flashes and 3 long flashes) indicate a limit circuit fault – this means that the high limit switch has been open. Such an error can appear if there’s a lack of airflow; changing the filter, opening the vents, and getting rid of any obstructions in the duct should help.Carrier Comfort 92 Furnace Error Code #13 and #33 Limit Circuit - YouTube. Chris Of All Trades. 7.47K subscribers. 98. 84K views 7 years ago. Fixing my carrier comfort 92 high efficiency...What happens is the furnace will run fine for a few hours and give 33 - Limit Fault. After some time it goes to 13 limit lockout and stops running. I usually end up power cycling it from the breaker and it works fine for another few hours and then same cycle repeats. Any help is appreciated.No heat. Nordyne G7 fault, Open limit switch Fault. 1. When unit is off, both red/green leds lit (normal), 2. once thermostat temp is raised, fan starts, aux fan on exhaust starts, Green LED flashes, … read moreOct 7, 2014 · code 13: limit circuit lockout code 33: limit circuit fault ... The most common cause of a limit trip is airflow thru the furnace. A dirty filter, clogged A/C coil ... The furnace will start up in either intermediate-, or maximum-heat. The furnace will transition and operate at minimum-heat or the calculated modulating rate after starting and operating for 45 seconds at intermediate-heat. The furnace control CPU defaults to minimum-heat on the first thermostat cycle and calculates the modulating rateLimit switches don’t usually wear out by themselves. They are a safety device that is never actually intended to be used. So it should last the life of the furnace. Even if they do get a lot of use (if an air filter gets neglected and clogged), the airflow issue can be corrected and the defective limit switch can be replaced.Troubleshooting the Open Limit Fault - YouTube. Nortek Global HVAC. 15.1K subscribers. Subscribed. 57. 15K views 6 years ago. Learn how to troubleshoot an open limit fault on a …the 33 is a limit, a limit would typically be any switch that break the 24volt circuit for the heat, could be the little discs the red wires attach to, by the inducer motor, the roll out switches, but if you can get the furnace to come back on without depressing any switches, it's probably the high limit, which means the unit if overheating.In this episode of Repair and Replace, Vance shows how to replace the high limit switch in a gas furnace. The limit switch is a safety switch that monitors t...How To Reset Furnace Limit Switch - Troubleshooting The Limit Switch On. Check Details. Ducane furnace model no. MPGA075B3B led fault code flashes 4 times high. Check Details. Fault Codes For Mid And High Efficiency Furnaces - YouTube. Check Details. My furnace was attempting to cycle and I read to clean the flame sensor. Check Details. Carrier ...Thermostat gives Airflow Verification Test results as follows: System CFM 1400. Static pressure 0.51. Blower RPM 938. Min CFM 364. Today I happened to be in the Furnace Status screen during when a 33 Limit Fault occurred. Took a photo to preserve. Here's what it said: gas heat 100%..